VPD Chart and Calculator for Every Growth Stage
Vapor Pressure Deficit (VPD) measures the difference in kilopascals (kPa) between moisture saturation inside the leaf and moisture in the surrounding grow tent air. Common grower targets are 0.4–0.8 kPa for Clone/Seedling, 0.8–1.2 kPa for Veg, 1.0–1.5 kPa for Early Flower, and 1.2–1.6 kPa for Late Flower.
Calculated from values you entered. This is not a live sensor reading.
1. Enter your environment
Range: 50–100 °F
Range: 0–100%
Range: −10 to +5 °F
Calculated from values you entered
1.06 kPa
Assumed leaf temp: 75.0 °F (23.9 °C)
Leaf SVP: 2.96 kPa
Air actual vapor pressure: 1.90 kPa
Illustrative estimate using an assumed leaf-temperature offset. No verified target status. Measure leaf temperature at the canopy and verify temperature/RH calibration before comparing with a stage target.
VPD chart by growth stage
This chart preserves the cited sources' reference ranges. Late Flower is 1.2–1.6 kPa here; Verdant's stage-aware calculator uses its canonical 1.1–1.5 kPa band. Reference bands for hypothetical values, not a verified target status for your plants.
Clone/Seedling (0.4–0.8 kPa)
Veg (0.8–1.2 kPa)
Early Flower (1.0–1.5 kPa)
Late Flower (1.2–1.6 kPa)
Overlapping band rule: cells matching Veg: 0.8–1.2 kPa are marked with a star. Nearest current input: 76 °F / 60% RH.
| Air °F \ RH % | 30% | 35% | 40% | 45% | 50% | 55% | 60% | 65% | 70% | 75% | 80% | 85% | 90% |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 60 °F | |||||||||||||
| 62 °F | |||||||||||||
| 64 °F | |||||||||||||
| 66 °F | |||||||||||||
| 68 °F | |||||||||||||
| 70 °F | |||||||||||||
| 72 °F | |||||||||||||
| 74 °F | |||||||||||||
| 76 °F | |||||||||||||
| 78 °F | |||||||||||||
| 80 °F | |||||||||||||
| 82 °F | |||||||||||||
| 84 °F | |||||||||||||
| 86 °F | |||||||||||||
| 88 °F | |||||||||||||
| 90 °F |
Sources: Spider Farmer blog (Clone/Seedling 0.4–0.8 kPa, Veg 0.8–1.2 kPa), Gorilla Grow Tent VPD chart guide (Early Flower 1.0–1.5 kPa), Aroya VPD chart (Late Flower 1.2–1.6 kPa). Common grower targets, not strict rules. Updated Oct 2026.
How VPD is calculated
Saturation vapor pressure (SVP) in kPa is calculated from temperature T in °C (where °C = (°F − 32) / 1.8), and VPD compares saturation at the leaf against actual moisture in the air.
SVP = 0.61078 × exp(17.27T / (T + 237.3))
VPD = SVP(leaf) − SVP(air) × RH/100
Worked example: at 77 °F, 60% RH, and a leaf offset of −2 °F, the result is 1.06 kPa.
FAQ
What is a good VPD for veg?
Common grower target is 0.8–1.2 kPa (Spider Farmer).
What VPD should I run in early flower?
Common target is 1.0–1.5 kPa (Gorilla Grow Tent).
What VPD is best for late flower?
Common target is 1.2–1.6 kPa (Aroya).
Does leaf temperature change VPD?
Yes. VPD uses leaf temperature for the saturation side, so a cooler leaf lowers VPD at the same air temperature and humidity.